Inspection program
Escalator and moving walkway inspection
DOB's elevator rule defines "elevator" to include escalators and moving walkways, so they carry the same yearly CAT1 test cycle, January 1 to December 31. For an escalator the agency must notify DOB at least 5 calendar days before the CAT1, and the report is due 21 days after the test. We price each escalator separately and coordinate with an approved agency.
| Line | Price |
|---|---|
| Escalator or moving walkway CAT1, per device | Get a price |
You get a per-device price before we schedule any work. A building with escalators and elevators gets one quote that lists every device.
Which devices are covered
Escalators and moving walkways in any building. The elevator rule's definition takes in elevators, escalators, moving walkways, material lifts and other conveying devices. The owner arranges the inspections.
Escalators sit mostly in commercial buildings. Commercial lots in our count carry 114 escalators on small lots, 564 on mid-rise lots and 589 on tower lots, out of 2,595 active escalators citywide (public city records, counted November 20, 2026).
Who may do the work
An approved elevator agency whose directors and inspectors are licensed. Category tests are witnessed by approved independent third-party agencies. DOB publishes a separate escalator periodic inspection checklist next to the elevator one.
How often
The CAT1 cycle under the rule runs January 1 to December 31 of each year, and the rule counts escalators as elevators. Before an escalator CAT1, the agency gives DOB at least 5 calendar days' notice. Elevators don't need that notice for a CAT1.
Reports, defects and penalties
- Report due: 21 days after a category test, 14 days after a periodic inspection.
- Defects: corrected within 90 days, hazardous conditions immediately, with an affirmation of correction filed within 14 days of the fix.
- Missing CAT1 or periodic report: $3,000 per device in commercial and mixed-use buildings, since the rule's penalties are written per elevator and its definition includes escalators.
What we coordinate
We coordinate with an approved agency and send you the filed report. Quotes are per device. We don’t repair escalators, replace your maintenance company or promise a deadline.
Questions
What are escalator inspection requirements in NYC?
Escalators fall under DOB's elevator rule, which runs the CAT1 cycle from January 1 to December 31 each year. The agency must give DOB 5 calendar days' notice before an escalator CAT1, and the report is due 21 days after the test. Defects are corrected within 90 days.